AQUA T3 Device Information : General Introduction

Device Information
General Introduction
Slide for Features & Benefits
User¡¯s Comment
Case Presentation
AMC Experience
European Experience
Japanese Experience
Outstanding Deliverability
Pushability, Trackability, Crossability

The arrival of drug-eluting stents has heralded a new era in interventional cardiology with the cardiologist now able to treat a much broader range of patients and lesions than ever before.

As a PTCA balloon's journey is becoming increasingly demanding (i.e. reaching a distal lesion through tortuous anatomy or crossing a tight or total occlusion), Cordis has designed the Aqua T3¢â, a PTCA balloon that will provide you with outstanding deliverability and procedural safety when treating the most challenging lesions.

Please click on the circles for more information :

Click here! Click here! Click here!

Procedural Safety
Low Compliance

When preparing a tight lesion prior to stent placement, you want to limit the injury to the vessel.(1)

Cordis low compliant Duralyn¢â balloon material:

• inflicts less stress on the arterial wall than more compliant balloons
• minimizes the risk of dissection
• reduces vessel trauma at higher pressures

A wide range of balloon lengths and diameters

Inflated Balloon
Diameter (mm)

Balloon Length
10 mm
15 mm
20 mm
30 mm
40 mm
1,50
60110150*
60115150*
60120150*
1,50
60110152
60115152
60120152
2,00
60110200
60115200
60120200
60130200
60140200
2,25
60110225
60115225
60120225
60130225
60140225
2,50
60110250
60115250
60120250
60130250
60140250
2,75
60110275
60115275
60120275
60130275
60140275
3,00
60110300
60115300
60120300
60130300
60140300
3,25
60110325
60115325
60120325
60130325
60140325
3,50
60110350
60115350
60120350
60130350
60140350
4,00
60110400
60115400
60120400
60130400
60140400

* Italic Bold Text represents itemcodes of 1.5 mm balloons with 1 marker band
Technical information

• Proximal shaft 1.9 F
• Distal Shaft 2.7 F
• Usable Length 140 cm
• Distal shaft length 25 cm
• Exit markers 100 cm and 90 cm
• Nominal Pressure 8 atm
• Rated Burst Pressure 14 atm
• Balloon Markers Dual Embedded*
• Balloon Coating Hydrophilic AquaSLX
• Balloon Material Duralyn

* Crossing Profile Test set-up: The balloon catheter is advanced at constant force through pinholes of different diameters. The results show the average of the smallest hole the atheter can penetrate by at least 50% of the balloon length. The secondary profile is etermined by the same procedure after two consecutive inflations of the balloon to Rated Burst Pressure.
(1) Rogers C, Tseng DY, Squire JC, Edelman ER. Balloon-artery interactions during stent placement. Circ Res. 1999; 84:378-383.
 