The
CLASSIC NM™ PTCA Dilatation Catheter is
designed to allow for easy exchange of balloon
catheter using all standard PTCA guidewires.
The proximal shaft is composed of a polymer coated
stainless steel hypotube, on which printed markers
are located to help identify catheter position
relative to the tip of the guiding catheter when
either a brachial or femoral approach is applied.
The distal segment of the balloon catheter contains
a stainless steel corewire to facilitate superior
pushability even through tortuous vasculature.
The semi-compliant nylon balloon material allows
for high-pressure dilatation while maintaining
control of balloon size. The Duraloob™ hydrophilic
coating on the balloon enhances crossability through
complex lesions. Two radiopaque platinum marker
bands are located within the balloon to indicate
balloon worklength.
CLASSIC NM™ PTCA Dilatation Catheter is
compatible with all standard 0.014 inch guidewires.
The design of this dilatation catheter does not
incorporate a lumen for distal dye injections
and distal pressure measurements. |
| |
| • |
Stainless steel tapered
corewire for better pushability |
| • |
One of the lowest profile among its
group |
| • |
Duraloob™ Hydrophilic coating |
|
|
|
|
| - One of the Highest
Rated Burst Pressure in the market @ 16 atm
|
| |
|
| - Semi Compliant balloon
material to allow controlled balloon dilatation
|
| |
|
| - Short Balloon Shoulder
to avoid edge dissection |
| - Dual Wing Hub for
Easy gripping by operator |
|
|
|
| Proximal shaft |
Hypotube
|
 |
| Proximal
Shaft Diameter |
2.4 F |
 |
| Distal Shaft Diameter
|
2.7
F |
 |
| Transition Prox./Dist.
Shaft |
Tri-Extrusion |
 |
| Balloon Material |
Nylon
12 |
 |
| Compliance |
Semi |
 |
| Nominal Pressure |
8
atm |
 |
| Rated Burst Pressure
|
16
atm |
 |
| Profile 3.0 mm |
0.030" |
 |
| Lesion Entry Profile
|
0.016" |
 |
| Marker Bands |
2
Platinum / Iridium |
 |
| Tip Design |
Flex
Tip |
 |
| Coating |
Hydrophilic |
 |
| Balloon Pleat |
3 |
 |
| Inner Lumen Size |
0.0155"
to 0.0165" |
 |
|

Guidewire exit port is located 24 cm from
the distal tip of the balloon catheter.
|
|
|
| |
| |
| |
| Reference No. |
Balloon
diameter |
Balloon
length |
 |
| 101-1515 |
1.5
mm |
15
mm |
 |
| 101-1520 |
1.5
mm |
20
mm |
 |
| 101-2015 |
2.0
mm |
15
mm |
 |
| 101-2020 |
2.0
mm |
20
mm |
 |
| 101-2030 |
2.0
mm |
30
mm |
 |
| 101-2220 |
2.25
mm |
20
mm |
 |
| 101-2230 |
2.25
mm |
30
mm |
 |
| 101-2515 |
2.5
mm |
15
mm |
 |
| 101-2520 |
2.5
mm |
20
mm |
 |
| 101-2530 |
2.5
mm |
30
mm |
 |
| 101-2540 |
2.5
mm |
40
mm |
 |
|
| Reference No. |
Balloon
diameter |
Balloon
length |
 |
| 101-2720 |
2.75
mm |
20
mm |
 |
| 101-2730 |
2.75
mm |
30
mm |
 |
| 101-3015 |
3.0
mm |
15
mm |
 |
| 101-3020 |
3.0
mm |
20
mm |
 |
| 101-3030 |
3.0
mm |
30
mm |
 |
| 101-3040 |
3.0
mm |
40
mm |
 |
| 101-3520 |
3.5
mm |
20
mm |
 |
| 101-3530 |
3.5
mm |
30
mm |
 |
| 101-4020 |
4.0
mm |
20
mm |
 |
| 101-4030 |
4.0
mm |
30
mm |
 |
| 101-4040 |
4.0
mm |
40
mm |
 |
|
|
|
|
|
|
|