Both femoral arteries were punctured with 6 Fr sheaths, and then two 8 Fr Proglide devices were placed into each of two femoral puncture sites. With a 6 Fr pigtail catheter, aortography was done via left femoral artery ( Movie 1). A 0.035 inch Lunderquist stiff wire was inserted via right femoral artery and a 20 Fr sheath was placed. An Endurant 20Fr bifurcated stent graft system (28mm [proximal diameter] x 16mm [distal diameter]/120mm in length) was deployed via right femoral sheath ( Movie 2, Movie 3). And then, a 0.035 inch Lunderquist stiff wire was inserted via left femoral artery and a 14 Fr sheath was placed. An Endurant 14Fr contralateral limb stent graft system (16x16mm/120mm) was deployed at left common iliac artery ( Movie 4). The balloon dilatation was done with a Reliant 10-46mm balloon at stent body and both bifurcated branches (Figure 3, Figure 4, Figure 5). Follow-up angiogram showed type I endoleak at proximal attachment, and we considered that right distal fixation length could not be enough ( Movie 5). So additional balloon dilatation was done at proximal attachment and an Endurant 14Fr contralateral limb stent graft system (16x16mm/80mm) was deployed at right common iliac artery ( Movie 6) and several balloon dilatations were done. After that, final angiogram showed successful exclusion of AAA with trivial endoleak at proximal attachment ( Movie 7). After the intervention, both puncture sites were sutured by two prepared Proglides at each site. |