Vascular accesses were obtained by insertion of two 7 Fr sheathes into both femoral arteries, and aortography was performed via right femoral artery using a 5 Fr pigtail diagnostic catheter ( Movie 1). We dilated the right femoral artery using 14 Fr and 18 Fr sheath dilator and then inserted and deployed the Endurant Stent Graft System 23-14-14mm/103 mm from AAA to right common iliac artery ( Movie 2, Figure 3). An Endurant Contralateral limb (16-10mm/93 mm) was deployed at left common iliac artery (Figure 4). We inserted two 14 Fr sheaths into both femoral arteries. Then, an Endurant Iliac Extension (16-13mm/93mm) was deployed at right common iliac artery ( Movie 3, Figure 5). The balloon dilatation was performed via left and right femoral artery with a Reliant balloon 46mm balloon at stent body and both bifurcated branches (Figure 6, Figure 7). Final angiogram showed successful exclusion of AAA without significant endoleak ( Movie 4). After the intervention, both puncture sites were closed by manual compression.
|